混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液

聂发辉, 李文婷, 刘占孟, 刘玉清. 混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液[J]. 环境工程学报, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
引用本文: 聂发辉, 李文婷, 刘占孟, 刘玉清. 混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液[J]. 环境工程学报, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
Nie Fahui, Li Wenting, Liu Zhanmeng, Liu Yuqing. Treatment of landfill leachate by coagulation precipition-Fenton-NaClO oxidation[J]. Chinese Journal of Environmental Engineering, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
Citation: Nie Fahui, Li Wenting, Liu Zhanmeng, Liu Yuqing. Treatment of landfill leachate by coagulation precipition-Fenton-NaClO oxidation[J]. Chinese Journal of Environmental Engineering, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713

混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液

  • 基金项目:

    国家自然科学基金资助项目(51148006,51468016)

    江西省自然科学基金资助项目(20142BAB203023,20142BAB203027)

  • 中图分类号: X703

Treatment of landfill leachate by coagulation precipition-Fenton-NaClO oxidation

  • Fund Project:
  • 摘要: 用混凝沉淀-Fenton-NaClO氧化联合深度处理垃圾渗滤液,利用单因素变量法得出:混凝实验在PFS投加量为1.2 g/L、pH=6、搅拌时间为30 min的条件下进行,COD、氨氮和色度的去除率分别达到56.60%、15.62%和56.52%;混凝出水在初始pH为4、H2O2投加量为80 mmol/L、n(H2O2):n(F2+)比为1:1、反应时间为60 min的条件下进行Fenton氧化,COD、氨氮和色度的去除率分别达到71.38%、21.43%和95.24%;Fenton氧化出水在pH为6、NaClO投加量为60 mmol/L、反应时间为60 min的条件下进行NaClO氧化,COD和氨氮去除率分别为83.42%和99.57%;联合工艺COD、氨氮和色度去除率分别为96.68%、99.69%和98.04%,出水浓度分别为63 mg/L、0.47 mg/L和18倍,均可满足《生活垃圾填埋污染控制标准(GB16889-2008)》中规定的排放标准。
  • 加载中
  • [1] 王昶,张思月,酒井裕司,等.Fenton氧化反应过程中存在铁系络合物的初步分析.天津科技大学学报,2014,29(2):20-24 Wang Chang,Zhang Siyue,Sakai Yuji,et al.Analysis of iron-based complex in fenton oxidation process.Journal of Tianjin University of Science & Technology,2014,29(2):20-24(in Chinese)
    [2] 张淑娟,赵琰,张琤琦,等.微波强化Fenton降解甲醛废水的研究.应用化工,2014,43(3):492-494,497 Zhang Shujuan,Zhao Yan,Zhang Zhengqi,et al.Degradation of formaldehyde wastewater with microwave enhanced Fenton.Applied Chemical Industry,2014,43(3):492-494,497(in Chinese)
    [3] Davarnejad R.,Moraveji M.K.,Pirhadi M.,et al.Simulation of landfill leachate treatment using electro-Fenton technique.Water Science and Technology,2014,69(2):343-349
    [4] 陈云嫩,刘春花,范景彪,等.Fenton 氧化降解垃圾渗滤液中COD的动力学研究.环境工程学报,2013,7(7):2574-2578 Chen Yunnen,Liu Chunhua,Fan Jingbiao,et al.Study on kinetics of treating COD from landfill leachate by Fenton oxidation.Chinese Journal of Environmental Engineering,2013,7(7):2574-2578(in Chinese)
    [5] Amr S.S.A.,Aziz H.A.New treatment of stabilized leachate by ozone/Fenton in the advanced oxidation process.Waste Management,2012,32(9):1693-1698
    [6] 胡小兵,赵鑫,刘孔辉.次氯酸钠氧化法去除电镀废水中的氨氮.电镀与涂饰,2014,(5):214-216 Hu Xiaobing,Zhao Xin,Liu Konghui.Removal of ammonia nitrogen from pretreated electroplating wastewater by oxidation with sodium hypochlorite.Electroplating & Finishing,2014,(5):214-216(in Chinese)
    [7] 张胜利, 刘丹, 曹臣.次氯酸钠氧化脱除废水中氨氮的研究.工业用水与废水,2009,40(3):23-26 Zhang Shengli,Liu Dan,Cao Chen.Removal of ammonia-nitrogen from wastewater by sodium hypochlorite oxidization.Industrial Water & Wastewater,2009,40(3):23-26(in Chinese)
    [8] 陆贤,刘伟京,涂勇,等.次氯酸钠氧化法深度处理造纸废水试验研究.环境科学与技术,2011,34(3):90-92 Lu Xian,Liu Weijing,Tu Yong,et al.Experimental study on advanced treatment of papermaking wastewater by NaClO Process.Environmental Science & Technology,2011,34(3):90-92(in Chinese)
    [9] 王昶,黄志金,左军,等.次氯酸钠氧化脱除河水低浓度氨氮研究.中国市政工程,2013,13(2):39-42
    [10] 杨涛,傅金祥,梁建浩.次氯酸钠预氧化处理微污染水源水的试验.工业用水与废水,2005,36(6):14-16 Yang Tao,Fu Jinxiang,Liang Jianhao.Experiment of treatment of slightly polluted source water using sodium hypochlorite pre-oxidation process.Industrial Water & Wastewater,2005,36(6):14-16(in Chinese)
    [11] 肖灵,程斌,莫建松,等.次氯酸钠湿法烟气脱硝及同时脱硫脱硝技术研究.环境科学学报,2011,31(6):1175-1180 Xiao Ling,Cheng Bin,Mo Jiansong,et al.Removal of NO and SO2 from flue gas by wet scrubbing using aqueous NaClO solution.Acta Scientiae Circumstantiae,2011,31(6):1175-1180(in Chinese)
    [12] 国家环境保护总局.水和废水监测分析方法(第4版).北京:中国环境科学出版社,2002:216-218,279-280
    [13] 朱帅帅,柴涛.曝气+化学絮凝法预处理环氧丙烷废水.环境工程学报,2014,8(2):605-611 Zhu Shuaishuai,Chai Tao.Pretreatment of epoxy propane wastewater by aeration chemical flocculation.Chinese Journal of Environmental Engineering,2014,8(2):605-611(in Chinese)
    [14] 高盼盼,吕春芳,曹鹏华.混凝-Fenton法预处理垃圾渗滤液的实验研究.应用化工,2013,42(9):1672-1674,1677 Gao Panpan,Lü Chunfang,Cao Penghua.Study of landfill leachate pretreatment by coagulation-Fenton process.Applied Chemical Industry,2013,42(9):1672-1674,1677(in Chinese)
    [15] 高艳娇,黄继国,聂广正,等.Fenton氧化法深度处理垃圾渗滤液.工业用水与废水,2005,36(6):39-41 Gao Yanjiao,Huang Jiguo,Nie Guangzheng,et al.Advanced treatment of landfill leachate by Fenton oxidation process.Industrial Water & Wastewater,2005,36(6):39-41(in Chinese)
  • 加载中
计量
  • 文章访问数:  2087
  • HTML全文浏览数:  1489
  • PDF下载数:  515
  • 施引文献:  0
出版历程
  • 收稿日期:  2014-07-15
  • 刊出日期:  2015-07-02
聂发辉, 李文婷, 刘占孟, 刘玉清. 混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液[J]. 环境工程学报, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
引用本文: 聂发辉, 李文婷, 刘占孟, 刘玉清. 混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液[J]. 环境工程学报, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
Nie Fahui, Li Wenting, Liu Zhanmeng, Liu Yuqing. Treatment of landfill leachate by coagulation precipition-Fenton-NaClO oxidation[J]. Chinese Journal of Environmental Engineering, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713
Citation: Nie Fahui, Li Wenting, Liu Zhanmeng, Liu Yuqing. Treatment of landfill leachate by coagulation precipition-Fenton-NaClO oxidation[J]. Chinese Journal of Environmental Engineering, 2015, 9(7): 3153-3158. doi: 10.12030/j.cjee.20150713

混凝沉淀-Fenton-NaClO氧化深度处理垃圾渗滤液

  • 1. 华东交通大学土木建筑学院, 南昌 330013
基金项目:

国家自然科学基金资助项目(51148006,51468016)

江西省自然科学基金资助项目(20142BAB203023,20142BAB203027)

摘要: 用混凝沉淀-Fenton-NaClO氧化联合深度处理垃圾渗滤液,利用单因素变量法得出:混凝实验在PFS投加量为1.2 g/L、pH=6、搅拌时间为30 min的条件下进行,COD、氨氮和色度的去除率分别达到56.60%、15.62%和56.52%;混凝出水在初始pH为4、H2O2投加量为80 mmol/L、n(H2O2):n(F2+)比为1:1、反应时间为60 min的条件下进行Fenton氧化,COD、氨氮和色度的去除率分别达到71.38%、21.43%和95.24%;Fenton氧化出水在pH为6、NaClO投加量为60 mmol/L、反应时间为60 min的条件下进行NaClO氧化,COD和氨氮去除率分别为83.42%和99.57%;联合工艺COD、氨氮和色度去除率分别为96.68%、99.69%和98.04%,出水浓度分别为63 mg/L、0.47 mg/L和18倍,均可满足《生活垃圾填埋污染控制标准(GB16889-2008)》中规定的排放标准。