收尘区脉冲供电对电除尘器收集性能的影响
Influence of pulse supply in collecting area on collection performance of electrostatic precipitator
-
摘要: 建立了双区电除尘器实验模型,研究了预荷电压、不同供电方式下极板间距、电极型式对双区电除尘器收尘效果的影响。结果表明:随着预荷电压逐渐升高,除尘效率也随之增加,双区除尘效果明显优于单区的除尘效果。脉冲供电对电除尘器的除尘性能影响明显,与直流供电相比,脉冲供电对PM2.5的分级效率可提高16.9%;在较高的电压时,极板间距为400 mm的除尘效率明显高于间距为300 mm的除尘效率,同时其驱进速度也有很大的提高;芒刺电极收尘效果显著优于光滑电极;对小于20 μm的颗粒,脉冲放电提高其驱进速度平均为54.22%。Abstract: The two-stages electrostatic precipitator (ESP) model was set up. The dust collection efficiency of two-stages electrostatic precipitator (ESP) was investigated under different parameters, including pre-charge voltage, power supply mode, electrode-plate space distance, and electrode type. The result showed that the dust collection efficiency of two-stages ESP increased with increasing of pre-charge voltage, and was better than that of single-stage ESP. The dust collection efficiency under pulse power was better than that under DC supply power; as to PM2.5, which grade efficiency is over 16.9% highter than that of in DC supply power.The dust collection efficiency at electrode-plate space distance 400 mm was higher than that of at 300 mm, and the migration was depply enhanced. Nail electrode had a more contribution than smooth electrode under same base supply voltage. The migration velocity of PM20 under pulse power was over 54.22% highter than that under DC supply power.
-
-

计量
- 文章访问数: 2042
- HTML全文浏览数: 987
- PDF下载数: 986
- 施引文献: 0