O3/GAC-常规处理珠江水系不同原水

吴悦, 吴纯德, 胡冰, 梁佳莉. O3/GAC-常规处理珠江水系不同原水[J]. 环境工程学报, 2014, 8(2): 520-524.
引用本文: 吴悦, 吴纯德, 胡冰, 梁佳莉. O3/GAC-常规处理珠江水系不同原水[J]. 环境工程学报, 2014, 8(2): 520-524.
Wu Yue, Wu Chunde, Hu Bing, Liang Jiali. Purification of different raw waters of Pearl River using O3/GAC-conventional treatment[J]. Chinese Journal of Environmental Engineering, 2014, 8(2): 520-524.
Citation: Wu Yue, Wu Chunde, Hu Bing, Liang Jiali. Purification of different raw waters of Pearl River using O3/GAC-conventional treatment[J]. Chinese Journal of Environmental Engineering, 2014, 8(2): 520-524.

O3/GAC-常规处理珠江水系不同原水

  • 基金项目:

    国家自然科学基金资助项目(51078148,41173103)

    国家“水体污染控制与治理”科技重大专项(2009ZX07423-003)

  • 中图分类号: X522

Purification of different raw waters of Pearl River using O3/GAC-conventional treatment

  • Fund Project:
  • 摘要: 以东江、西江和北江3种原水为研究对象,采用臭氧预处理-常规处理-臭氧活性炭系列处理,研究原水中有机物的去除及臭氧化副产物的产生和转化。结果表明,东江、西江和北江水中CODMn、UV254、甲醛和溴酸盐沿各处理单元过程变化规律基本一致;CODMn总去除率分别为60%、51%和39%,UV254总去除率分别为74%、96%和97%,最终出水甲醛浓度分别为0.004 mg/L、0 mg/L和0 mg/L,BrO3-分别为3.1 μg/L、8.7 μg/L和35.5 μg/L;CODMn的去除主要在预臭氧和活性炭过滤2个处理单元,预臭氧对UV254总去除率贡献最大,甲醛和溴酸盐浓度在主臭氧处理单元达到其峰值(西江甲醛除外);氨氮和有机物浓度较低、pH值较高的北江原水,出水溴酸盐浓度最高。
  • 加载中
  • [1] 陈明媚. 珠江流域水污染治理的问题与对策. 广州: 华南理工大学硕士学位论文, 2011 Chen M. M. On the issues and countermeasures to water pollution treatment in the Pearl River Basin. Guangzhou: Master Dissertation of South China University of Technology, 2011 (in Chinese)
    [2] GB5749-2006. 生活饮用水卫生标准. 北京: 中华人民共和国卫生部, 2006
    [3] 贺道红, 高乃云, 曾文慧, 等. 臭氧生物活性炭深度处理黄浦江上游原水. 中国给水排水, 2006, 22(1): 13-17 He D. H., Gao N. Y., Zeng W. H., et al. Pilot-scale study on advanced treatment of Huangpu River upper reaches raw water by ozone-BAC. China Water & Wastewater, 2006, 22(1): 13-17 (in Chinese)
    [4] 李思敏, 赵南南, 李志广. 臭氧/活性炭工艺深度处理微污染水源水的中试. 中国给水排水, 2011, 27(11): 45-47 Li S. M., Zhao N. N., Li Z. G. Pilot study on advanced treatment of micro-polluted source water by O3/GAC process. China Water & Wastewater, 2011, 27(11): 45-47 (in Chinese)
    [5] Kim K. S., Oh B. S., Kang J. W., et al. Effect of ozone and GAC process for the treatment of micro-pollutants and DBPs control in drinking water: Pilot scale evaluation. Ozone Sci. Eng., 2005, 27(1): 69-79
    [6] Melnick R. L. An alternative hypothesis on the role of chemically induced protein droplet nephropathy in renal carcinogenesis. Regulatory Toxicol and Pharmacol, 1992, 16(3): 111-125
    [7] 孔令宇, 张晓健, 王占生. 臭氧-生物活性炭与单独活性炭工艺处理效果比较. 中国给水排水, 2006, 22(11): 49-51 Kong L. Y., Zhang X. J., Wang Z. S. Comparison of performance between O3-BAC and GAC processes. China Water & Wastewater, 2006, 22(11): 49-51 (in Chinese)
    [8] 李璇, 吕锡武, 朱光灿. 臭氧-生物活性炭工艺处理黄浦江微污染原水的中试研究. 水处理技术, 2007, 33(11): 53-56 Li X., Lv X. W., Zhu G. C. Pilot studies on ozone-biological activated carbon process for treating micro-polluted raw water in Huangpu Jiang River. Technology of Water Treatment, 2007, 33(11): 53-56 (in Chinese)
    [9] 黄小红, 鄢敏林, 石鲁娜. 太湖原水净化过程中有机物分子量分布特性研究. 供水技术, 2011, 5(6): 6-9 Huang X. H., Yan M. L., Shi L. N. Molecular weight distribution of organic matters in water purification process for Taihu Lake raw water. Water Technology, 2011, 5(6): 6-9 (in Chinese)
    [10] 郭召海, 杨敏, 张昱, 等. 预臭氧与后臭氧-生物活性炭联用工艺研究. 环境科学, 2005, 26(6): 79-83 Guo Z. H., Yang M., Zhang Y., et al. Study on the combination of preozonation and post-ozonation-BAC process for drinking water treatment. Environmental Science, 2005, 26(6): 79-83 (in Chinese)
    [11] 金鹏康, 王晓昌, 王洪波. 水中腐植酸的臭氧化特性研究. 西安建筑科技大学学报, 2000, 32(4): 334-337 Jin P. K., Wang X. C., Wang H. B. A study on the characteristics of ozonation of aquatic humic substances. J.Xi'an Univ. of Arch. & Tech., 2000, 32(4): 334-337 (in Chinese)
    [12] Ferguson D. W., Gramith J. T., McGuire M. J. Applying ozone for organics control and disinfection: A utility perspective. AWWA, 1993, 85(1): 64-71
    [13] 陆少鸣, 王宁, 杨立. O3-BAC给水深度处理工艺的优化运行. 华南理工大学学报, 2006, 34(12): 10-14 Lu S. M., Wang N., Yang L. Operation optimization of O3-BAC advanced treatment process for drinking water. Journal of South China University of Technology (Natural Science), 2006, 34(12): 10-14 (in Chinese)
    [14] Can Z. S., Gurol M. D. Formaldehyde formation during ozonation of drinking water. Ozone: Science & Engineering, 2003, 25(1): 41-51
    [15] von Gunten U. Ozonation of drinking water: part Ⅱ. disinfection and by-product formation in presence of bromide, iodide or chlorine. Water Res., 2003, 37(7): 1469-1487
    [16] von Gunten U., Hoigne J. Bromate formation during ozonation of bromide-containing waters: Interaction of ozone and hydroxyl radical reactions. Environmental Science & Technology, 1994, 28(7): 1234-1242
    [17] 施东文, 谢曙光, 汪蕊, 等. 生物炭形成过程对溴酸盐和有机物的去除能力研究. 中国给水排水, 2006, 22(19): 5-7 Shi D. W., Xie S. G., Wang R., et al. Removal of bromate and organic substances during transition from fresh activated carbon to BAC. China Water & Wastewater, 2006, 22(19): 5-7 (in Chinese)
    [18] Asami M., Aizawa T., Morioka T., et al. Bromate removal during transition from new granular activated carbon(GAC) to biological activated carbon(BAC). Water Research, 1999, 33(12): 2797-2804
    [19] Amirsardari Y., Yu Q., Williams P. Effect of ozonation and UV irradiation with direct filtration on disinfection and disinfection by-product precursors in drinking water treatment. Environmental Technology, 2001, 22(9): 1015-1023
  • 加载中
计量
  • 文章访问数:  1717
  • HTML全文浏览数:  898
  • PDF下载数:  770
  • 施引文献:  0
出版历程
  • 收稿日期:  2013-03-15
  • 刊出日期:  2014-01-27
吴悦, 吴纯德, 胡冰, 梁佳莉. O3/GAC-常规处理珠江水系不同原水[J]. 环境工程学报, 2014, 8(2): 520-524.
引用本文: 吴悦, 吴纯德, 胡冰, 梁佳莉. O3/GAC-常规处理珠江水系不同原水[J]. 环境工程学报, 2014, 8(2): 520-524.
Wu Yue, Wu Chunde, Hu Bing, Liang Jiali. Purification of different raw waters of Pearl River using O3/GAC-conventional treatment[J]. Chinese Journal of Environmental Engineering, 2014, 8(2): 520-524.
Citation: Wu Yue, Wu Chunde, Hu Bing, Liang Jiali. Purification of different raw waters of Pearl River using O3/GAC-conventional treatment[J]. Chinese Journal of Environmental Engineering, 2014, 8(2): 520-524.

O3/GAC-常规处理珠江水系不同原水

  • 1.  华南理工大学环境与能源学院, 广州 510006
  • 2.  工业聚集区污染控制与生态修复教育部重点实验室, 广州 510006
基金项目:

国家自然科学基金资助项目(51078148,41173103)

国家“水体污染控制与治理”科技重大专项(2009ZX07423-003)

摘要: 以东江、西江和北江3种原水为研究对象,采用臭氧预处理-常规处理-臭氧活性炭系列处理,研究原水中有机物的去除及臭氧化副产物的产生和转化。结果表明,东江、西江和北江水中CODMn、UV254、甲醛和溴酸盐沿各处理单元过程变化规律基本一致;CODMn总去除率分别为60%、51%和39%,UV254总去除率分别为74%、96%和97%,最终出水甲醛浓度分别为0.004 mg/L、0 mg/L和0 mg/L,BrO3-分别为3.1 μg/L、8.7 μg/L和35.5 μg/L;CODMn的去除主要在预臭氧和活性炭过滤2个处理单元,预臭氧对UV254总去除率贡献最大,甲醛和溴酸盐浓度在主臭氧处理单元达到其峰值(西江甲醛除外);氨氮和有机物浓度较低、pH值较高的北江原水,出水溴酸盐浓度最高。