倏逝波免疫传感器超灵敏检测水样中的双酚A

李伟, 吴君, 王浩宇, 杨荣, 宋丹, 龙峰. 倏逝波免疫传感器超灵敏检测水样中的双酚A[J]. 环境化学, 2018, 37(2): 347-352. doi: 10.7524/j.issn.0254-6108.2017061401
引用本文: 李伟, 吴君, 王浩宇, 杨荣, 宋丹, 龙峰. 倏逝波免疫传感器超灵敏检测水样中的双酚A[J]. 环境化学, 2018, 37(2): 347-352. doi: 10.7524/j.issn.0254-6108.2017061401
LI Wei, WU Jun, WANG Haoyu, YANG Rong, SONG Dan, LONG Feng. Ultrasensitive detection of BPA in water using an evanescent wave immunosensor[J]. Environmental Chemistry, 2018, 37(2): 347-352. doi: 10.7524/j.issn.0254-6108.2017061401
Citation: LI Wei, WU Jun, WANG Haoyu, YANG Rong, SONG Dan, LONG Feng. Ultrasensitive detection of BPA in water using an evanescent wave immunosensor[J]. Environmental Chemistry, 2018, 37(2): 347-352. doi: 10.7524/j.issn.0254-6108.2017061401

倏逝波免疫传感器超灵敏检测水样中的双酚A

  • 基金项目:

    国家重大科技专项(2012YQ030111)和国家自然科学基金(21675171)资助.

Ultrasensitive detection of BPA in water using an evanescent wave immunosensor

  • Fund Project: Supported by the National Key Science and Technology Projects(2012YQ030111) and Evanescent Wave Nanobiosensor for the On-Site Real-Time Parallel Detection of Pathogenic Bacteria (21675171).
  • 摘要: 基于间接竞争免疫分析和全内反射原理,利用研发的便携式倏逝波光纤免疫传感实现水样中双酚A(BPA)的快速、灵敏、定量检测.优化了检测条件,结果表明在抗体浓度为1 μg·mL-1、预反应时间为6 min、光纤反应时间为450 s时既能得到有效的信号值又能节约时间.选择性实验结果表明其他污染物对传感器不产生干扰,该传感器具有良好的特异性.再生性实验显示,200次检测周期后传感器仍然保持良好的再生性能.评估了磷酸盐缓冲液(PBS)、自来水和圆明园水的基质效应,建立了不同水样双酚A的标准曲线,对应的检测限分别为0.032、0.033、0.039 μg·L-1;相对标准偏差在3%以内,表明该传感器具有很好的稳定性和精确度,能用于实际水样中双酚A的快速检测.
  • 加载中
  • [1] YILDIRIM N,LONG F,HE M,et al. A portable optic fiber aptasensor for sensitive,specific and rapid detection of bisphenol-A in water samples[J]. Environmental Science Processes & Impacts,2014,16:1379-1386.
    [2] LONG F,ZHU A N,ZHOU X H,et al. Highly sensitive and selective optofluidics-based immunosensor for rapid assessment of Bisphenol A leaching risk[J]. Biosensors and Bioelectronics,2014,55(1):19-25.
    [3] 韩霜. 分子印迹技术及其研究进展[D]. 大庆:东北石油大学,2014. HAN S. Molecule imprinting technology and its research progress[D]. Daqing:Northeast Petroleum University,2014(in Chinese).
    [4] KIM A,LI C R,JIN C F,et al. A sensitive and reliable quantification method for bisphenol A based on modified competitive ELISA method[J]. Chemosphere,2007,68:1204-1209.
    [5] FENG Y,NING B A,SU P,et al. An immunoassay for bisphenol A based on direct hapten conjμgation to the polystyrene surface of microtiter plates[J]. Talanta,2009,80:803-808.
    [6] ZHANG J,ZHAO S Q,Zhang K,et al. Cd-doped ZnO quantum dotsbased immunoassay for the quantitative determination of bisphenol A[J]. Chemosphere,2014,95:105-110.
    [7] XUE J Q,LI D W,LU L L,et al. Surface-imprinted core-shell Au nanoparticles for selective detection of bisphenol A based on surface-enhanced Raman scattering[J]. Analytica Chimica Acta,2013,777:57-62.
    [8] HAO X J,ZHOU X H,ZHANG Y,et al. Melamine detection in dairy products by using a reusable evanescent wave fiber-optic biosensor[J]. Sensors and Actuators B,2014,204:682-687.
    [9] RUDEL R A,GRAY J M,ENGEL C L,et al. Food packaging and bisphenol A and bis(2-ethyhexyl) phthalate exposure:Findings from a dietary intervention[J]. Environmental Health Perspectives,2011,119(7):914-920.
    [10] LONG F,SHI H C,HE M,et al. Sensitive and rapid detection of 2,4-dicholorophenoxyacetic acid in water samples by using evanescent wave all-fiber immunosensor[J]. Biosensors and Bioelectronics,2008,23:1361-1366.
    [11] 龙峰,施汉昌,王洪臣,等.用于1.3-二硝基苯快速检测的免疫传感器研究[J]. 环境科学, 2014. 35(4):1561-1565.

    LONG F,SHI H C,WANG H C,et al. Immunosensor for rapid detection of 1,3-dinitrobenzene[J]. Environment Science,2014,35(4):1561-1565(in Chinese).

    [12] 娄雪宁,周丽萍,宋丹,等. 乙腈和正己烷对环境特征污染物免疫传感分析的影响[J]. 环境科学,2016,37(1):391-396.

    LOU X N,ZHOU L P,SONG D,et al. Effect of acetonitrile and n-hexane on the Immunoassay of environmental representative pollutants[J]. Environment Science,2016,37(1):391-396(in Chinese).

    [13] SLOVACEK R E,FURLON S C,LOVE W F. Feasibility Study of a plastic evanescent-wave sensor[J]. Sensor Actuator B,1993,11(1-3):307-311.
    [14] HUA P, HOLE P,WILKINSON J S,et al. Integrated optical fluorescence multisensor for water pollution[J]. Optics Express,2005,13:1124-1130.
    [15] SHENG J W,HE M,SHI H C,et al. A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies[J]. Analytica Chimica Acta,2006,572:309-315.
    [16] GUO H L,ZHOU X H,ZHANG Y,et al. Highly sensitive and rapid detection of melamine in milk products by planar waveguide fluorescence immunosensor (PWFI)[J]. Sensors and Actuators B,2014,194:114-119.
    [17] LOU X N,ZHU A N,WANG H L,et al. Direct and ultrasensitive optofluidic-based immunosensing assay of aflatoxin M1 in dairy products using organic solvent extraction[J]. Analytica Chimica Acta,2016,940:120-127.
  • 加载中
计量
  • 文章访问数:  915
  • HTML全文浏览数:  854
  • PDF下载数:  351
  • 施引文献:  0
出版历程
  • 收稿日期:  2017-06-14
  • 刊出日期:  2018-02-15

倏逝波免疫传感器超灵敏检测水样中的双酚A

  • 1. 中国人民大学环境学院, 北京, 100872
基金项目:

国家重大科技专项(2012YQ030111)和国家自然科学基金(21675171)资助.

摘要: 基于间接竞争免疫分析和全内反射原理,利用研发的便携式倏逝波光纤免疫传感实现水样中双酚A(BPA)的快速、灵敏、定量检测.优化了检测条件,结果表明在抗体浓度为1 μg·mL-1、预反应时间为6 min、光纤反应时间为450 s时既能得到有效的信号值又能节约时间.选择性实验结果表明其他污染物对传感器不产生干扰,该传感器具有良好的特异性.再生性实验显示,200次检测周期后传感器仍然保持良好的再生性能.评估了磷酸盐缓冲液(PBS)、自来水和圆明园水的基质效应,建立了不同水样双酚A的标准曲线,对应的检测限分别为0.032、0.033、0.039 μg·L-1;相对标准偏差在3%以内,表明该传感器具有很好的稳定性和精确度,能用于实际水样中双酚A的快速检测.

English Abstract

参考文献 (17)

目录

/

返回文章
返回